Space-Saving & Versatile Design
Vertical or Horizontal Roll-Up: Adapts to tight spaces with minimal overhead clearance.
Custom Sizes & Configurations: Available for large openings (e.g., up to 10m wide × 6m high) and curved tracks.
Why Choose Us?
Tested & Certified – Meets international fire safety standards
Durable & Low-Maintenance – Long-lasting performance
Custom Solutions – Tailored to your space and needs
Automated or Manual Options – For convenience and security
Key Benefits for Industrial Parks:
High Fire Resistance (60/90/120 mins) – Certified to delay fire spread between units
Durable & Weatherproof – Withstands harsh conditions (wind, dust, corrosion)
Automated & Remote-Controlled – Smooth operation for high-traffic zones
Forced-Entry Protection – Reinforced steel construction deters theft & vandalism
Custom Sizes & Speeds – Tailored for warehouses, factories, and loading docks
Invest in Safety Today! Contact us for a FREE consultation and fire risk assessment.
Galvanized Steel Fire Door
Characteristics
UNMATCHED FIRE RESISTANCE
CERTIFIED PROTECTION: ENGINEERED TO MEET INTERNATIONAL STANDARDS (E.G., EN 16034, UL 10B/C), WITH FIRE RATINGS FROM 1 TO 4 HOURS (CLASS A PER GB14102).
HEAT-ACTIVATED AUTOMATION
HEAT-ACTIVATED AUTOMATION: AUTOMATICALLY DEPLOYS UPON DETECTING HEAT OR SMOKE, INTEGRATING WITH FIRE ALARM SYSTEMS FOR INSTANT RESPONSE.
STRUCTURAL INTEGRITY
HEAVY-DUTY MATERIALS: CONSTRUCTED WITH GALVANIZED STEEL OR ALUMINUM ALLOY SLATS, REINFORCED WITH STEEL GUIDES FOR IMPACT RESISTANCE.
Certification Standard
EN16034: the overarching standard for pedestrian and industrial fire/smoke doors & shutters. it mandates assessment against:
EN 1634-1: fire resistance test for doors, shutters, and operable fabric curtains (integrity, insulation)
EN 1364-2: fire resistance tests for non-loadbearing elements - part 2: ceilings (relevant for shutter boxes/cassettes).
EN 1363-1/2: general fire resistance test methods.
EN 13501-2: classification using test data from above
UL 10B / UL 10C: standard fire tests for door assemblies.
UL 263: standard for fire tests of building construction and materials (similar scope to ASTM 119).
Technical data
FIRE RATING | > or =3–4 HOURS (TESTED TO GB9978/EN 1634) | TYPES, APPLICATIONS & BENEFIT | |
BACKFACE TEMPERATURE | AVG. > or =380°C; MAX. SINGLE POINT > or = 180°C | ① DUAL-TRACK DUAL-CURTAIN | |
CURTAIN THICKNESS | 10–20 MM (MULTI-LAYER: CERAMIC FIBER + FIREPROOF CLOTH) | LARGE MALLS, ATRIUMS, INDUSTRIAL ZONES | |
OPERATION SPEED | 2.5–6.4 M/MIN (ELECTRIC); 4–5 M/MIN (GRAVITY FALL) | AIR-LAYER INSULATION; NO WATER SPRAY | |
AIR GAP (DUAL CURTAINS) | 300 MM (OPTIMIZES THERMAL INSULATION) | ② WATER-MIST STEEL SHUTTER | |
SOUND INSULATION | UP TO 42 DB REDUCTION | HIGH-HUMIDITY AREAS (E.G., PARKING GARAGES) | |
MOTOR POWER | 0.25–1.5 KW (AC/DC OPTIONS) | RAPID COOLING; SMOKE SUPPRESSION | |
MAX. DIMENSIONS | WIDTH: < or = 60 FT (18.3 M); HEIGHT: < or = 40 FT (12.2 M) | ③ FOLDABLE LIFT-TYPE | |
STRUCTURAL REQUIREMENTS | IRREGULAR OPENINGS (E.G., ESCALATORS, CURVED WALLS) | ||
WALL STRENGTH | MUST SUPPORT 300–500 KG LOADS; CONCRETE/BRICK WALLS RECOMMENDED. | SPACE-SAVING; COLUMN-FREE DESIGN | |
OPENING TOLERANCE | ≤5 MM DEVIATION (PLUMB/LEVEL) FOR SEAMLESS TRACK ALIGNMENT. | ④ INSULATED STEEL (FIRESTAR) | |
APPLICATION | BUILDING PROJECT, COMPANY, HOME, OFFICE, HOTEL, CHURCH, JUST ANYWHERE YOU WANT! | EXTREME CLIMATES (E.G., COLD STORAGE) | |
PACKAGE | INSIDE: PE PAPER | OUTSIDE: DOUBLE LAYERS CARTON BOX AND WOODEN PALLETS. | MINERAL WOOL CORE; U-VALUE < or = 0.8 W/M²K |
Doors Overviews
RELATED SOLUTIONS